What was found
CRACK INDICATION FOUND ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 203.1 AND 23 INCH. FROM FRONT SPAR. CRACK LENGTH = 0.800 INCH. APPROX. 2022-409903 / [01] EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 190023010; DUE DATE: 14-FEB-23.;[02] ET TOOL USED: PN: MIZ-21C ; SN: 769680; DUE DATE: 07-JUL-23;[03] PERFORMED REPAIR ON HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 203.1 AND 23 INCH. FROM FRONT SPAR I.A.W. EA#22-155-02528-WIP1 AND EA#22-155-02528. SEE INDIVIDUAL SIGN-OFF BELOW;[04] CORRECTED STEP 3<BR>PERFORMED REPAIR ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 203.1 AND 23 INCH. FROM FRONT SPAR I.A.W. EA#22-155-02528-WIP1 AND EA#22-155-02528. SEE INDIVIDUAL SIGN-OFF BELOW;[05] PERFORMED REPAIR ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 203.1 AND 23 INCH. FROM FRONT SPAR I.A.W. EA#22-155-02528-WIP1 AND EA#22-155-02528. SEE INDIVIDUAL SIGN-OFF BELOW.<BR>CERTIFIED AS RII.