As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 460+2. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 460+2' REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS2678 EXP 4/2023. FLOOR TO SIDEWALL SUPPORT WILL BE REMOVED AND REPLACED FROM BS 400 TO BS 500I ON FAULT TTG8Q00E5E0E.;[02] VERIFIED ACTION #1;[03] VERIFIED MEASUREMENT FIELD