What was found
CRACK ON FWD CARGO BAY O/B BAFFLE TO FRAME ATTACH ANGLE AT LBL 24 BS 500H+1. / [01] CLIP FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION #1;[03] REMOVED BAFFLE ANGLE AT BS 500H+1 LBL 24 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW BAFFLE ANGLE AT BS 500H+1 LBL 24 PER SRM 51-40-05-0G-0 AND DWG 143A7505;[05] OK TO INSTALL BFFLE ATTACH ANGLE;[06] VERIFIED CORRECTIVE ACTION STEPS 4 AND 5. VERIFIED OK TO INSTALL.;[07] INSTALLED BAFFLE ATTACH ANGLE AT BS 500H+1 LBL 24 PER SRM 51=40-02-0G-0 AND DWG 143A7505;[08] VERIFIED CORRECTIVE ACTION #7;[09] VERIFIED CORRECTIVE ACTION #7