What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500G+2; BS 500G+7; BS 500G+15; BS 500G+20; BS 500H+2; BS 500H+7; BS 500H+11; BS 500H+15. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500H+7'' REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS2678 EXP 4/2023. FLOOR TO SIDEWALL SUPPORT WILL BE REMOVED AND REPLACED FROM BS 500A TO BS 500I ON FAULT TTG8Q00E5E11;[02] VERIFIED CORRECTIVE ACTION 1<BR><BR>VERIFIED MEASUREMENTS TABLE