What was found
CORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 480+14. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1<BR><BR>VERIFIED MEASUREMENTS TABLE;[03] REMOVED DAMAGED SHIELD AT RBL 24 BS 492 -BS 500A PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW SHIELD AT RBL 24 BS 492 -BS 500A PER SRM 51-40-05-0G-0 AND DWG 143A0080.<BR>OK TO INSTALL;[05] VERIFIED ACTION #4; OK TO INSTALL GIVEN;[06] UPDATED OK TO INSTALL SHIELD;[07] OK TO INSTALL GIVEN ON CORRECTIVE ACTION #5;[08] INSTALLED SHIELD AT RBL 24 BS 492 -BS 500A PER SRM 51-40-02-0G-0 AND DWG 143A0080;[09] VERIFIED CORRECTIVE ACTION #8