What was found
FLOOR PANEL 222BF HAS TORN PLIES ON UPPER SURFACE IN SEVERAL LOCATIONS (MARKED) / [01] IDENTIFIED MATERIAL IAW SRM 53-00-50-0I-1 TABLE 2 FIG 2.<BR><BR>DAMAGE NOTED IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1<BR><BR>REMOVED DAMAGE TO UPPER SURFACE PLIES THEN CLEANED REPAIR AREA. FABRICATED REPAIR PLIES FROM BMS9-3 H2 ST 1581 LOT#1493221-1; OK TO INSTALL IAW SRM 53-00-50-2R-1 PARA 3C-F;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] VERIFIED CORRECTIVE ACTION ITEMS 1 AND 2.<BR>OKAY TO INSTALL REPAIR PLIES.;[04] INSTALLED REPAIR PLIES USING BMS8-201 TYPE 3 LOT#AK2CP8139K; VACUUM BAGGED; CHECKED FOR LEAKS; LEAK CHECKED GOOD USING VACUUM GAUGE ATS2107 CAL DUE DATE 09/2022 IAW SRM 53-00-50-2R-1 PARA 3K-L;[05] VERIFIED CORRECTIVE ACTION ITEM 4.;[06] CURED REPAIR PLIES UNDER HEAT LAMP USING THERMOMETER ID:ATS2208 DUE:10/2022; UNBAGGED; AND TRIMMED EXCESS MATERIAL IAW SRM 53-00-50-2R-1 PAR.3 M(1);[07] VERIFIED CORRECTIVE ACTION 6<BR><BR>VERIFIED MEASUREMENTS TABLE;[08] UPLOADED CURE SHEET AND VERIFIED COMPLETION OF REPAIRS IAW SRM 53-00-50-2R-1;[09] VERIFIED CORRECTIVE ACTION 8;[10] VERIFIED CORRECTIVE ACTION 8