What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS344+9 LBL11. / [01] REQUEST NDI TO VERIFY CRACK FREE CONDITION ON INTERCOSTAL AT FWD WET AREA BS344+9 LBL11.;[02] HFEC INSPECTED OPEN HOLES IAW 737 NDTM PART 6 51-00-00 PROCEDURE 16. <BR>NO CRACKS NOTED. <BR>EQUIP USED: <BR>-NORTEC 600 ID: ATS2353 CAL DUE: 01/23 <BR>-MINIMITE ID: ATS1411 CAL DUE: 07/23;[03] UPON FURTHER INVESTIGATION INTERCOSTAL AT FWD WET AREA BS344+9 LBL11 WL 208 WAS FOUND TO BE IN CRACK FREE CONDITION.;[04] HFEC INSPECTED SURFACE AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>CRACK NOTED TO BE 0.6'. FOUND ADJACENT TO THE AFT FASTENER HOLE. MARKED ENDS OF CRACK.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS2353 CAL DUE: 01/23;[05] UPDATED MEASUREMENT TABLE.;[06] REMOVED CRACKED INTERCOSTAL AT FWD WET AREA BS344+9 LBL11 WL 208 PER SRM 51-40-02.;[07] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS344+9 LBL11 WL208 PER SRM 51-40-05 AND DWG#141A5400. REQUEST OK TO INSTALL.;[08] VERIFIED ACTION #6-7 OK TO INSTALL GIVEN;[09] INSTALLED INTERCOSTAL AT FWD WET AREA BS344+9 LBL 11 PER SRM 51-40-02-0G-0 AND DWG 141A5400;[10] VERIFIED INSTALLATION OF INTERCOSTAL AT FWD WET AREA BS344+9 LBL 11;[11] RII INSPECTION ACCOMPLISHED;[12] ALL STEPS COMPLETE