What was found
CRACK FOUND ON UPPER ATTACH ANGLE AT STA 663 OUTBOARD SIDE OF LBL 45 WL 193. VERIFIED WITH HFEC / [01] DISPLACED WIRING BONDLE AFT SIDE OF REPAIR AREA IAW SRM 51-40-02-0G-0;[02] VERIFIED STEP 1 C/W;[03] ACCOMPLISHED FUEL LEAK CHECK OF CNT TANK FASTENERS IAW AMM 28-11-00-210-801<BR>LEAK CHECK GOOD;[04] VERIFIED STEP 3 C/W;[05] REINSTALLED DISPLACED WIRE BUNDLE AFT OF REPAIR AREA (MAIN WHEEL WELL) IAW SWPM 20-10-12 PARA D;[06] VERIFIED STEP 5 C/W;;[07] VERIFIED UPPED ATTACH ANGLE AT STA 663 LBL 45 WAS REPAIRED IAW EA 22-157-02625;[08] VERIFIED ITEM 7<BR>AUDIT C/W