What was found
DOT A-24-5 MID CABIN FLOOR PANEL 232SF HAS COMPOSITE PULLED FIBERS ON UPPER SIDE. / [01] EVALUATED AND FOUND DAMAGE TO UPPER SURFACE TO BE REPAIRABLE IAW SRM 53-00-50-2R-0 REPAIR GENERAL TABLE 201 REPAIR 1<BR>CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50-2R-1 STEPS 3 A;C;E;F.<BR>VERIFIED REPAIR MATERIALS AS GLASS--(A10269); RESIN--(A141868) IAW SRM 53-00-50-2R-1 TABLE 201<BR>NEED OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEPS 3 K-M. TAP TEST GOOD. TOOLING AAR30347 DUE 4-30-23;[04] REPAIRED DAMAGE TO UPPER SURFACE FLOOR BOARD IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1 REPAIR 1. TAP TEST GOOD.;[05] VERIFIED STEPS 3-4