As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HFEC INDICATION OF A .50 INCH LONG CRACK IN ANGLE ON O/B SIDE OF FWD GALLEY DOOR FRAME BS 294.5 RBL 55.5 WL 208 / [01] REMOVED CRACK FLOOR ATTACH ANGLE AT FRAME 294.5 RBL 55.5 WL 208 IAW SRM 51-40-02;[02] LOCATED AND DRILLED NEW ATTACH ANGLE PER SRM 51-40-05; TREATED AND PRIMED HOLES PER SRM 51-20-01;[03] OK TO INSTALL NEW DRILLED ATTACH ANGLE.;[04] INSTALLED NEW ATTACH ANGLE PER SRM 51-40-02;[05] VERIFIED INSTALLATION OF NEW ATTACH ANGLE.