What was found
CRACK ANGLE LOCATED AT BS 1016 BETWEEN S-3R AND S-3L WL 308.5 AT VERTICAL STABILIZER 2022-426896 / [01] REPLACED ANGLE AND FASTENERS LOCATED AT BS 1016 BETWEEN S-3R AND S-3L WL 308.5 AT VERTICAL STABILIZER IAW B737-700 SRM 51-40-02 SRM 51-10-02 AND DWG 176A3001 SHEET 17 REV = ? SEE INDIVIDUAL SIGN-OFF BELOW.;[02] REPLACED ANGLE AND FASTENERS LOCATED AT BS 1016 BETWEEN S-3R AND S-3L WL 308.5 AT VERTICAL STABILIZER IAW B737-700 SRM 51-40-02 SRM 51-10-02 AND DWG 176A3001 SHEET 17 REV = ? SEE INDIVIDUAL SIGN-OFF BELOW.