What was found
CORROSION AT STRINGER 23R TO BULKHEAD FRAME CONNECTION AT BS 540. OUT OF LIMITS IAW SRM 53-00-03-1A-1 TABLE 101. CUTOUT DAMAGED AREA AT END STRINGER 23R BS 540; DIMENSION OF CUT: 1.000' X 1.000' IAW SRM 51-10-02, DRILLED EXISTING FASTENERS HOLES AT REPAIR SECTION OF S-23R IAW SRM 53-00-03-2R-1 & 51-40-05. INSTALLED REPAIR STRINGER AND SPLICE AT STRINGER 23 RH PER WIP 2 AND SRM 53-00-03-2R -1. ACCOMPLISHED REPAIR IAW EA: 22-153-02642. INSTALLED STRINGER CLIP AT S-23R; BS 520 IAW SRM 51-40-02. ACCOMPLISHED REPAIR IAW 22-153-02642.