What was found
SMELLED FUMES & HAD SMOKE/HAZE IN CABIN / [01] T/SHOT PER FIM 21-00 TASK 806. PERFORMED CHECK OF RECIRC FAN; EQUIP COOLING FANS; TEMP SENSOR FANS ALL CK OK. HYDRAULIC SYSTEM QTY NORMAL WITH NO LEAKS. RAN BOTH ENGS AT IDLE WITH LEFT ENG BLEED/PACK OPERATING AND RT ENG BLEED/PACK. NO ODORS SMOKE OR HAZE NOTED. PERFORMED T/O POWER RUN AND AGAIN ISOLATED AND RAN BLEEDS/PACKS WITH NO DEFECTS NOTED. REF AMM 71-00-00 FOR ENGINE RUN. FOUND AFT GALLEY O/B COFFEE MAKER OVERFLOWS AND BURNER PLATE CONTAMINATED. R AND R COFFEE MAKER CKS OK REF AMM 25-30-01. C/W COND INSP 05-51-56