What was found
CORROSION AT STRINGER 23L TO BULKHEAD FRAME CONNECTION AT BS 540. OUT OF LIMITS IAW SRM 53-00-03-1A-1 TABLE 101. CUT OUT DAMAGED AREA AT END OF STRINGER 23L BS 540; DIMENSION OF CUT: 0.900' X 1.000'; IAW SRM 51-10-02. FABRICATED REPLACEMENT STRINGER IAW SRM 53-00-03-2R-1. -FABRICATED FILLER IAW SRM 53-00-03 REPAIR 1 AND WIP 1;STEP 25. INSTALLED STRINGER CLIP AT STA 520 STR. 23L IN REF SRM 51-40-02-0G. ACCOMPLISHED REPAIR AT S-23L; BS 540; AS PER EA: 22-153-02678. CARD: TTG8Q00EJXAD.