What was found
CORROSION ON INTERCOSTAL; STA 951; LBL 25; WL 208. / [01] UPDATED MEASUREMENTS. VERIFIED SRM APPLICABILITY STATEMENT ALLOWABLE DAMAGE PER SRM 53-70-51-1A-1. ALSO; INTERCOSTAL AT BS 951 LBL25 WL208 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-40-51-1A-1 STEP 1.C AND PART REPLACEMENT PER SRM 51-10-02-0G-0 STEP 9.;[02] INSPECTED & VERIFIED CORRECTIVE ACTION ITEM 1; EXCEPT MEASUREMENT FIELDS.;[03] REMOVED FLOOR SUPPORT BS947-BS967 LBL25 WL208 I.A.W SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW FLOOR SUPPORT BS947-BS967 LBL25 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5650. OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4.<BR>OK TO INSTALL;[06] INSTALLED NEW INTERCOSTAL BS947-BS967 LBL25 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 147A5650 COMPLETED ALL REMOVED AND REPLACED TASK;[07] VERIFIED CORRECTIVE ACTION 6;[08] VERIFIED MEASUREMENT TABLE