What was found
6 EMERGENCY EXIT LIGHTS INOP. RIGHT HAND STOW BINS 7 AND 8; L2 DOOR HEADER PANEL; AFT ENTRY; G4 AND R2 EXTERIOR EMERGENCY EXIT LIGHTS / [01] PERFORMED A TEST OF EMERGENCY EXIT LIGHTS PER AMM 33-51-00-710 AND WDM 33-51-14. DETERMINED THAT BATTERY PACKS M1672 AND M1673 ARE NOT CHARGING.;[02] REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT BATTERY PACKS M1672 AND M1673 AND PERFORMED A SATISFACTORY INSTALLATION TESTS IAW AMM 33-51-06-960-805.;[03] VERIFIED CORRECTIVE ACTION 1 AND 2 COMPLETED;[04] ALL MAINTENANCE COMPLETED FOR THE CARD.