What was found
CORROSION ON AFT CARGO BAY RAIL AT RBL 3 BS 767+6. / FOUND TO BE OUT OF LIMITS BY DAMAGE LOCATION ; WILL BE REPAIR AS GIVEN SRM 53-00-53-2R-2 REPAIR 2. THE EFFECTIVITY SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 & SRM 53-60-53-0I-2 ARE APPLICABLE TO A/C N7878A. RECEIVED REPAIR CHANNEL WITH P/N: 53100004-001; LOT: 1499876-1; LOCATED AND DRILLED BTW BS 767+6; RBL3.IAW. SRM 51-40-05-0G-0; SRM 53-00-53-2R-2 REPAIR 2 PARAG. 4.I.(5). FIG. 203. SHEET10 & DWG# 53100004 OK TO INSTALL.;[04] REJECTED; CARGO RAIL DAMAGE HAS BEEN CUTOUT AT BS 767 + 6. THERE IS NO DOCUMENTATION IN THE AMT MXI UPDATE TO MATCH REPAIR ACTION AND COURSE OF ACTION; AND NDT REQUEST IS NEEDED PER SRM.;[05] LATE ENTRY: PERFORMED TRIMOUT ON AFT CARGO BAY RAIL AT RBL 3 BS 767+6' MEASURE : L=2.34' X W=.8' IAW SRM 53-00-53-2R-2. REPAIR 2 .<BR> ALTERNATIVE 5;[06] REQUEST NDI BY FREE CRACK CONDITION PER SRM 53-00-53-2R-2 REPAIR 2 PARAG.4.E. OK TO INSTA;[07] NDT HFEC INSPECTED TRIM OUT AREA IAW 737 NDTM PART 6 51-00-00 PROC 23. <BR>NO CRACKS NOTED <BR>EQUIP USED: NORTEC 500D IS000681 DUE 02/23;[08] VERIFIED CORRECTIVE ACTION ITEM 3-7; OK TO INSTALL REPAIR CHANNEL..;[09] INSTALLED ON ACB REINFORCING CHANNEL AT JOGGLE LOCATION BS 767 + 6 RBL.3 IAW SRM 51-40-02-0G-0; SRM 53-00-53-2R-2 REPAIR 2. ALTERNATIVE 5. FIG.103 SHEET 10.;[10] INSTALLED ON ACB REINFORCING CHANNEL AT JOGGLE LOCATION BS 767 + 6 RBL.3 IAW SRM 51-40-02-0G-0; SRM 53-00-53-2R-2 REPAIR 2. ALTERNATIVE 5. FIG.103 SHEET 10