What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 767+3; BS 767+5; BS 767+7; BS 767+18; BS 787+10; BS 787+14; BS 787+18; BS 807+6. / [01] REMOVED CORROSION ON AFT CARGO BAY UPPER SURFACE FROM FLOOR TO SIDEWALL SUPPORT BTW. BS 767+3' - BS807+6' AND MAX. MATERIAL LOSS ON STEP#8. BS 807+6'; LBL 21 WL 156. IAW SRM 51-10-02. MEASURE: L=1.' X W=.85' X D=0.013' ORIGINAL THICKNESS IS 0.040' REMAINING THICKNESS IS 0.027' FOUND REWORKED AREAS OUT OF LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2 PARG. 4.A.(2) DETAIL D . USED TOOL: ID: ATS2472. S/N: UNKNOW. DUE DATE: 12/2022.;[02] VERIFIED APPLICABILITY OF SRM 53-00-53-1A-2.;[03] VERIFIED CORRECTIVE ACTION ITEM1-2; OUT OF LIMITS;[04] WILL BE COMPLETED WITH CARD #TTG8Q00EE3V1;REMOVAL AND INSTALLATION ACCOMPLISHED ON CARD AD ID:TTG8Q004EMMQ.ALL MAINTENANCE ACTION ARE COMPLETED REQUIRE FINAL BUY OFF.;[05] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE.