What was found
AFT FLOOR PANEL 241ZF UPPER SURFACE HAS PULLED STRANDS. / REMOVED DAMAGE TO UPPER SURFACE IAW SRM 53-00-50-2R-1 PARA 3.A; 3.C; 3.E-3.F WITH NO CONTAMINATION NOTED.;[02] VALIDATED APPLICABILITY OF REPAIR TO BE COMPLETED IAW SRM 53-00-50-2R-1.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTION 1 AND 2.;[04] VERIFIED MEASUREMENT TABLE;[05] FABRICATED REPAIR PLIES FROM BMS9-3 TYPE H2 STYLE 1581 LOT NUMBER 1493221-1 IAW SRM 53-00-50-2R-1 PARAGRAPH 3.K.(1).(A) OK TO INSTALL REPAIR PLIES.;[06] INSPECTED AND VERIFIED CORRECTIVE ACTION 5. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-1.;[07] INSTALLED PLIES WITH BMS8-201 CLASS III LOT NUMBER AK2EP8210K; VACUUM BAGGED AND VERIFIED 5X5 USING VACUUM GAUGE ID: ATS2441 DUE: 08/2023; IAW SRM 53-00-50-2R-1 PARAGRAPH 3.K.(1).(B-C) AND L.(1).;[08] INSPECTED AND VERIFIED CORRECTIVE ACTION 7. 5X5 LEAK CHECK PASSED PER 53-00-50-2R-1.;[09] SET REPAIR TO CURE USING HOTBONDER ID: NCX000526 DUE: 10/2022 IAW SRM 53-00-50-2R-1 PARAGRAPH 3.M.(1).;[10] CORRECTION TO ITEM 8 SHOULD BE SRM 53-00-50-2R-1.;[11] VERIFIED CURE COMPLETE; UNBAGGED AND TRIMMED REPAIR IAW SRM 53-00-50-2R-1 PARA 3.M(1).;[12] VERIFIED CORRECTIVE ACTIONS 9 AND 11;[13] INSTALLED REMOVED INSERTS WITH BMS5-107 CLASS 1 LOT NUMBER AK1KP9159K RESIN; CURED RESIN UNDER A HEAT LAMP USING THERMOMETER ID: ATS2209 DUE: 10/2022; TO MONITOR TEMPERATURE; WORK PERFORMED IAW SRM 53-00-50-2R-1 PARAGRAPH 3.N AND DRAWING 147A5810 SHEET 98