What was found
AFT CARGO PIT FLOOR PANEL 2ND FROM FWD HAS A CRACK APPROXIMATELY 2 FEET LONG; 1 1/2 INCHES FROM TRAILING EDGE / [01] OK TO CONTINUE PER MEL 25-16-01 SP 1B AUTH# 90887;[02] R/R AFT CARGO PIT FLOOR PANEL 2ND FROM FWD PER AMM 25-52-10
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO PIT FLOOR PANEL 2ND FROM FWD HAS A CRACK APPROXIMATELY 2 FEET LONG; 1 1/2 INCHES FROM TRAILING EDGE / [01] OK TO CONTINUE PER MEL 25-16-01 SP 1B AUTH# 90887;[02] R/R AFT CARGO PIT FLOOR PANEL 2ND FROM FWD PER AMM 25-52-10