What was found
EXTERIOR LH OVERWING EMERGENCY LT INOP. OK TO CONTINUE PER MEL 33-14-01; SP1. REPLACED CABIN LH OVERWING EMERGENCY LIGHTING POWER SUPPLY IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXTERIOR LH OVERWING EMERGENCY LT INOP. OK TO CONTINUE PER MEL 33-14-01; SP1. REPLACED CABIN LH OVERWING EMERGENCY LIGHTING POWER SUPPLY IAW AMM 33-51-06. OPERATIONAL CHECK GOOD.