What was found
FWD CARGO COMPARTMENT R TRANSITION ANGLE BETWEEN STA. 500A TO 500I HAS CORROSION. / [01] REMOVED CORROSION FROM FWD CARGO COMPARTMENT RT ZEE SIDEPLATE CHANNEL ASSEMBLY BETWEEN STA 500A TO STA 500D+11; RBL 21. FOUND BLENDED AREAS TO BE WITHIN ALLOWABLE LIMITS WITH LESS THEN .004? MATERIAL REMOVED IAW SRM 53-00-53-1A-2.;[02] VERIFIED 1. JOHN PRAMUK (TECHNICIAN); 10-SEP-2022 14:56 UTC <BR>REMOVED CORROSION FROM FWD CARGO COMPARTMENT RT ZEE SIDEPLATE CHANNEL ASSEMBLY BETWEEN STA 500A TO STA 500D+11; RBL 21. FOUND BLENDED AREAS TO BE WITHIN ALLOWABLE LIMITS WITH LESS THEN .004? MATERIAL REMOVED IAW SRM 53-00-53-1A-2.;[03] APPLIED ALODINE AND PRIMED AREAS IN COMMON WITH REPAIR FROM STA 500A TO 500D+11 PER SRM 51-20-01; 53-00-53-1A-2.;[04] VERIFIED 3. JOHN PRAMUK (TECHNICIAN); 10-SEP-2022 15:44 UTC <BR>APPLIED ALODINE AND PRIMED AREAS IN COMMON WITH REPAIR FROM STA 500A TO 500D+11 PER SRM 51-20-01; 53-00-53-1A-2;[05] CORROSION DAMAGE ON FWD CARGO COMPARTMENT RT ZEE SIDEPLATE CHANNEL ASSEMBLY BETWEEN STA 500D+11 TO 500I; RBL 21; FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2.;[06] SLICE RT ZEE SIDEPLATE CHANNEL LOCATED ON STA 500D +11 FOR REPAIR AND PART FABRICATION. ALL WORKS REFERENCE TO SRM 53-00-53-2R-6 INSTALLED R/H FWD CARGO REPAIR SPLICE TRANSITION ANGLE FROM STA 500E TO 500I. PER SRM 53-00-53-2R-5.