What was found
INTERCOASTAL - STA 380 TO 400 - LBL '13' - CRACKED / [01] INSTALLED EWIS PROTECTION AT MAIN CABIN UNDER FLOOR PANEL STA 380-TO STA 400 LBL-13' REF USED AMM 20-60-07-913-801;[02] REMOVED INTERCOASTAL AT MAIN CABIN FROM STA 380 TO STA 400 LBL-13' REF USED SRM 51-40-02-0G-0;[03] VERIFIED STEP 1 AND 2;[04] LOCATED AND DRILLED NEW HOLES AT INTERCOASTAL - STA 380 TO 400 - LBL '13' IN REF SRM 51-40-05-0G-0;TREATED AND APPLIED PRIMER IN REF SRM 51-20-01-0G;[12] INSTALLED EWIS PROTECTION AT MAIN CABIN UNDER FLOOR PANEL STA 380-TO STA 400 LBL-13' REF USED AMM 20-60-07-913-801;REMOVED INTERCOASTAL AT MAIN CABIN FROM STA 380 TO STA 400 LBL-13' REF USED SRM 51-40-02-0G-0;LOCATED AND DRILLED NEW HOLES AT INTERCOASTAL - STA 380 TO 400 - LBL '13' IN REF SRM 51-40-05-0G-0;TREATED AND APPLIED PRIMER IN REF SRM 51-20-01-0G;INSTALLED INTERCOASTAL AT MAIN CABIN FROM STA 380 TO STA 400 LBL-13' REF USED SRM 51-40-02-0G-0 AND DRAWING 143A5400 AND REMOVED EWIS PROTECTION AT MAIN CABIN UNDER FLOOR PANEL STA 380-TO STA 400 LBL-13' REF USED AMM 20-60-07-913-802;[13] VERIFIED STEP 10; 11; 12 AND 13