What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 AND WL 208.1 AFT FACE CENTER SECTION 2022-488574 / [01] REPLACED ANGLE LOC. ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 AND WL 208.1 AFT FACE CENTER SECTION I.A.W. B737-700 DWG 273A9110 SHEET 6 REV A AND SRM 51-40-0 AND SRM 51-10-02 ITEM 9 SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACED ANGLE LOC. ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 AND WL 208.1 AFT FACE CENTER SECTION I.A.W. B737-700 DWG 273A9110 SHEET 6 REV A AND SRM 51-40-0 AND SRM 51-10-02 ITEM 9 SEE INDIVIDUAL SIGN-OFF BELOW.AS RII.