What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 RBL 24.5 WL 208.1 CENTER SECTION 2022-488570 / [01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-23; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112820025; DUE DATE: 01-FEB-23;[02] REPLACED ANGLE LOC. ON ANGLE FLOOR STRUCTURE LOCATED AT BS 695 RBL 24.5 WL 208.1 CENTER SECTION I.A.W. B737-700 DWG 273A9110 SHEET 6 REV A AND SRM 51-40-0 AND SRM 51-10-02 ITEM 9 SEE INDIVIDUAL SIGN-OFF BELOW;[03] CORRECTED STEP 2<BR>REPLACED ANGLE LOC. ON FLOOR STRUCTURE LOCATED AT BS 695 RBL 24.5 WL 208.1 CENTER SECTION I.A.W. B737-700 DWG 273A9110 SHEET 6 REV A AND SRM 51-40-0 AND SRM 51-10-02 ITEM 9 SEE INDIVIDUAL SIGN-OFF BELOW;[04] REPLACED ANGLE LOC. ON FLOOR STRUCTURE LOCATED AT BS 695 RBL 24.5 WL 208.1 CENTER SECTION I.A.W. B737-700 DWG 273A9110 SHEET 6 REV A AND SRM 51-40-0 AND SRM 51-10-02 ITEM 9 SEE INDIVIDUAL SIGN-OFF BELOW.AS RII..