What was found
PASSENGER CABIN FWD ENTRY DOOR STOP FITTING WEB CRACKED BS295 S-16L. MARKED. / [01] HFEC INSPECTED SUSPECTED CRACKED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>CRACK WAS NOTED IN AREA MARKED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS2353 CAL DUE: 01/23;[02] VERIFIED APPLICABILITY OF SRM 53-10-15-01-1 FOR IDENTIFICATION AND SRM 53-10-15-1A-1 FOR ALLOWABLE LIMIT;[03] DAMAGE FOUND AT PASSENGER CABIN FWD ENTRY DOOR STOP FITTING WEB BS295 S-16L. CRACK FOUND 6'LONG FOUND TO OUT OF LIMIT IAW SRM 53-10-15-1A-1; 4G FIG 108-C;[04] VERIFIED CORRECTIVE ACTION #2; #3.;[05] REMOVED CRACKED WEB FROM FWD ENTRY DOOR BS 295 STR 16 IAW SRM 51-40-02-0G-0; LOCATED AND DRILLED NEW WEB P/N 141A8181-51 IAW SRM 51-40-05-0G-0 AND DWG#141A8181 REV-3 OK TO INSTALL;[06] VERIFIED CORRECTIVE ACTION #5.<BR>VERIFIED OK TO INSTALL REPAIR PARTS.;[07] INSTALLED THE NEW PASSENGER CABIN FWD ENTRY DOOR STOP FITTING WEB BS295 STR-16L IAW SRM 51-40-02-0G-0 AND DWG#141A8180;[08] VERIFIED CORRECTIVE ACTION 7 AND THE MEASUREMENT TABLE.;[09] VERIFIED WORKSCOPE IS COMPLETE.