What was found
MOPSILL INNER CHORD CRACKED BS 303.9 LBL 55 WL 209 / [01] UPDATED MEASUREMENTS. REMOVED FWD ENTRY DOOR MOPSILL IAW SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FED MOP SILL IAW SRM 51-40-05-0G-0 AND BOEING DWG 141A8110 APPLIED CHEMICAL CONVERSION COAT AND PRIMED ALL BARE METAL AREAS IAW SRM 51-20-01-0G-0 OK TO INSTALL;[03] OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION 2 AND 3; OK TO INSTALL GIVEN.;[05] INSTALLED FED MOP SILL IAW SRM 51-40-02-0G-0 AND BOEING DWGS 141A8110;141A0720;140A9810;[06] VERIFIED CORRECTIVE ACTION #5;[07] VERIFIED MEASUREMENT TABLE;[08] CARD COMPLETE