As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT CRACKED BS 312+9 LBL 43 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT BS 312+9 LBL 43 WL 208 PER SRM 51-40-02.;[02] LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-05; DRW # 141A5400. REQUEST OK TO INSTALL.;[03] VERIFIED CORRECTIVE ACTION #2<BR> OK TO INSTALL GIVEN;[04] INSTALLED NEW FLOOR SUPPORT AT BS 312+9 LBL 43 WL 208 PER SRM 51-40-02; DWG#141A5400.;[05] VERIFIED CORRECTIVE ACTION #4<BR>MEASUREMENT TABLE VERIFIED