What was found
ELECTRICAL GROUND POWER RECEPTACLE CRACKED ON THE LOWER CUTOUT DOUBLER LIP / TRIMMED OUT DAMAGE AREA ALONG EDGE L=3.5' AND PERFORMED DVI. NO ADDITTIONAL DAMAGE NOTED PER SRM 53-10-15-2R-4 PARAGRAPH 4.; FABRICATED; LOCATED AND DRILLED REPAIR PARTS (ZONE 2) -3 FILLER MADE FROM 2024T3X0.040 LOT# 1488474-1 AND -2 DOUBLER MADE FROM 7075T6X0.050 LOT#1300812-1 AND APPLIED CHEMICAL CONVERSION COATING PER SRM 53-10-15-2R-4 PARAGRAPH 4.E THRU K. TABLE 201 AND FIG 204 OK TO PRIME.;[10] VERIFIED CORRECTIVE ACTION ITEM 9. OKAY TO PRIME REPAIR PARTS GIVEN.;[11] PRIMED REPAIR PARTS -3 FILLER-2 DOUBLER AND BARE METAL AREAS PER SRM 53-10-15-2R-4 PARAGRAPH 4.K. OK TO INSTALL REPAIR PARTS AND REINSTALL RUBBING BLOCK.;[12] VERIFIED CORRECTIVE ACTION ITEM 11. OKAY TO INSTALL REPAIR PARTS AND RUBBING BLOCK.;[13] PRIMED WAS ON PER SRM 53-10-15-2R-4 PARAGRAPH 4.L INSTALLED REPAIR PARTS LISTED AT CORRECTIVE ACTION 11 PER SRM 53-10-15-2R-4 PARAGRAPH 4. M2 . THIS IS CATEGORY A REPAIR. NO FURTHER ACTION OR INSPECTION IS REQUIRED.;[14] VERIFIED CORRECTIVE ACTION ITEM 13. VERIFIED REPAIR PARTS INSTALLED.<BR>NOTED CORRECT REFERENCE FOR PRIMING PARTS.;[15] VERIFIED MEASUREMENT TABLE COMPLETED.