What was found
AFT CARGO RH FLOOR SUPPORT ANGLE CORRODED BELOW TRANSITION SHIELD AT STA. 767 TO 787. / [01] REMOVED CORROSION TRANSITION SHIELD AT STA. 767 TO 787PER SRM.51-10-02 ; MATERIAL FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-2 ;REMOVED AND REPLACED TRANSITION SHIELD AT STA. 767 TO 787 PER SRM.51-40-02;[02] INSPECTION C/W CORRECTIVE ACTION STEP 1.;[03] INSPECTION C/W CORRECTIVE ACTIONS STEP 1.;[04] CHANGED FAILED SYSTEM FROM 53-00 TO 53-98 PER TELECONFERENCE WITH E91274.