What was found
AFT CARGO R/H TRANSITION ANGLE STA. 727I- 747 HAS LIGHT SURFACE CORROSION AROUND SCREW HOLES. / [01] REMOVED LIGHT SURFACE CORROSION ON FASTENER HOLES AT TRANS ANGLE ATTACH FOUND TO BE BEYOND ACCEPTABLE LIMITS. MATERIAL REMOVED .006 AND REMAINING THICKNESS .034. REF SRM 51-10-02.;[02] REMOVED AFT CARGO R/H TRANSITION ANGLE FROM STA. 727G PLUS 10 TO 767 PER SRM 51-40-02;[03] LOCATED AND DRILLED NEW SECTION TRANSITION ANGEL FROM STA.727G+10 TO 767 PER SRM. 53-00-53-2R-5 ; TREATED AND PRIMED PER SRM . 51-20-02 ; INSTALLED NUT PLATES PER SRM.51-40-10;[04] INSTALLED NEW SECTION TRANSITION ANGEL FROM STA.727G+10 TO 767 PER SRM. 53-00-53-2R-5 ;;[05] INSTALLED NEW SECTION TRANSITION ANGEL FROM STA.727G+10 TO 767 PER SRM. 53-00-53-2R-5 ;;[06] VERIFIED C/A # 3 : TONY NGUYEN (TECHNICIAN); 20-SEP-2022 14:34 UTC<BR>LOCATED AND DRILLED NEW SECTION TRANSITION ANGEL FROM STA.727G+10 TO 767 PER SRM. 53-00-53-2R-5 ; TREATED AND PRIMED PER SRM . 51-20-02 ; INSTALLED NUT PLATES PER SRM.51-40-10;[07] VERIFIED C/A # 5 :5. TONY NGUYEN (TECHNICIAN); 21-SEP-2022 15:08 UTC<BR>INSTALLED NEW SECTION TRANSITION ANGEL FROM STA.727G+10 TO 767 PER SRM. 53-00-53-2R-5 ;;[08] C/W