What was found
UPON FLAP RETRACTION L INDICATOR STAYED IN 15 BAND R INDICATOR STAYED IN 25 BAND. FLAP MOVEMENT STOPPED / [01] R&R RT FLAP POSITION TRANSMITTER PER AMM 27-58-01. NO HELP;[02] R & R R/H #7 FLAP TRANSMISSION PER AMM 27-51-40 AND R & R R/H SEAL RIB ANGLE GEAR BOX PER AMM 27-51-57 OPS CHECK GOOD;[03] PERFORMED RII OF FLAP TRANSMISSION IAW AMM 27-51-40 AND SEAL RIB ANGLE GEARBOX IAW AMM 27-51-57;TORQUE TUBE INSTALL; RIG AND ADJUSTMENT