What was found
BS663 VAPOR BARRIER CRACKED AT LBL12 WL 152 / [01] IDENTIFIED PART MATERIAL IAW SRM 57-10-10-0I-2 FIG 2 TABLE 2 ITEM 4.<BR>DAMAGE WAS FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 57-10-10-1A-2 PARA 4.D(1).<BR>DAMAGE WILL BE REPAIRED IAW SRM 51-70-04-2R-10 PER SRM 57-10-10-2R-2 PARA 1.C(NOTE).<BR>REMOVED DAMAGE AND PREPARED REPAIR AREA IAW SRM 51-70-04-2R-10 PARA 4A-C.;[06] FABRICATED REPAIR PLIES FROM BMS 9-3H2 LOT#1502472-1 IAW SRM 51-70-04-2R-10 PARA 4.D. OK TO INSTALL.;[07] INSPECTED AND VERIFIED CORRECTIVE ACTION 6. OKAY TO INSTALL REPAIR PLIES PER SRM 51-70-04-2R-10.;[08] USING BMS9-3 H2 GLASS LOT 1502472-1 & BMS8-301 CL 1/EA9390 RESIN LOT JH1GAA7833 LAID UP THE REPAIR; VACUUM BAGGED LEAK CHECKED ;THEN SET TO CURE IAW SRM 51-70-04-2R-10 PARA 4. D. STEPS D & E.;[09] VERIFIED CORRECTIVE ACTION 8;[10] CURED PLIES; USING HOTBONDER ID: NCX000623 DUE: 06/2023 UNBAGGED AND LIGHTLY SANDED IAW SRM 51-70-04-2R-10 PARAGRAPH 4.F AND H.;[11] VERIFIED CORRECTIVE ACTION ITEM 10.;[12] REQUESTING POST CURE NDI OF REPAIR IAW SRM 51-70-04-2R-10 PAR. 4.G.;[13] UT INSPECTED REPAIR PER NDTM PART 4; 51-00-02. NO DISBONDS NOTED.<BR>EPOCH 650 CAL ID: ATS2341 S/N: 190848104 DUE: 06/2023;[14] REFINISHED REPAIR ARE IAW SRM 51-70-04-2R-10 PARAGRAPH 4.H;[15] VERIFIED CORRECTIVE ACTION ITEM 14. REPAIR COMPLETE.;[16] VERIFIED FAULT COMPLETE.