What was found
AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT STA 727D +3;+5;+8;+10.5;+3;+15;+18 TO 727E; RBL 23 TO 25; WL 157. / [01] REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D+3' IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D+8' IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D+10.5' IN L=2' X W=2' X D=0.006' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D+15' IN L=2' X W=2' X D=0.010' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D+18' IN L=2' X W=2' X D=0.008' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.USED TOOL:ID:ATS401S/N:UNKOWNDATE:10/2021DUE:10/2022;[02] WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9;