What was found
AFT CARGO BAY FLOOR FWD SHIELD HAS AREAS OF CORROSION STA 767 TO 787 WL 157. / [01] ENTERED MEASUREMENTS.;[02] B737-700 SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS EVALUATION.<BR>NO ALLOWABLE DAMAGE GIVEN IN SRM 53-00-53-1A-2 FOR THIS PART.<BR>REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.;[03] VERIFIED CORRECTIVE ACTION 1; 2 AND MEASUREMENT FIELD;[04] PROCURED NEW SHIELD; LOCATED AND DRILLED PER DWG 146A0081 REV:- ; SRM 51-40-05-0G-0; SRM 51-40-08-0G-0 AND SRM 51-40-04-0G-0.;[05] VERIFIED NEW PART DRILL UP; TASK COMPLETE