What was found
AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT STA 727C +2;+6;+10;+14;+15;+18 TO 727D RBL 23 TO 25; WL157. / [01] REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727C+2' IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727C+6' IN L=2' X W=2' X D=0.005' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727C+10' IN L=2' X W=2' X D=0.006' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727C+14' IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727C+18' IN L=2' X W=2' X D=0.005' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727D IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL EUSED TOOL:ID:ATS401S/N:UNKOWN<BR>DATE:10/2021<BR>DUE:10/2022;[02]WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9