What was found
AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT STA 727E 2;+6;+10;+14;+18 TO STA 747;RBL 23 TO 25; WL157. / [01] REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E+2' IN L=2' X W=2' X D=0.007' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E+6' IN L=2' X W=2' X D=0.009' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E+10' IN L=2' X W=2' X D=0.006' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E+14' IN L=2' X W=2' X D=0.008' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727E+18' IN L=2' X W=2' X D=0.005' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.<BR><BR>REMOVED CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 747 IN L=2' X W=2' X D=0.009' FROM ORIGINAL TICKNESS OF 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETAIL E.USED TOOL:ID:ATS401S/N:UNKOWNDATE:10/2021DUE:10/2022;[02] WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9