What was found
CRACKED INTERCOSTAL BS 312-328 WL 208 LBL 46. / [01] REMOVED DAMAGED INTERCOSTAL STA 312-328; LBL 46; WL 208 PER SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED AND DEBURRED INTERCOSTAL STA 312-328; LBL 46; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG# 141A5400. OK TO INSTALL.;[03] NO ALLOWABLE LIMITS FOUND SRM 51-10-02-0G-0 PAR 9.C IS APPLICABLE;[04] VERIFIED CORRECTIVE ACTIONS 2 AND 3.;[05] INSTALLED NEW INTERCOSTAL STA 312-328; LBL 46; WL 208 PER SRM 51-40-02-0G-0; BOEING DWG# 141A5400.COMPLETED REMOVED AND REPLACED TASK;[06] VERIFIED MEASUREMENT TABLE.;[07] VERIFIED CORRECTIVE ACTION 5.