What was found
BS 312 FRAME CRACKED AT STR. 5L LBL 32. / [01] NO ALLOWABLE LIMITS FOUND FOR BS312 FRAME CRACK DAMAGE TO BE REMOVED I.A.W SRM 51-10-02-0G-0 AND SUBMITTED TO ENG. FOR FURTHER INSTRUCTIONS;[02] REMOVED CRACK ON BS312 FRAME UPPER CHORD INNER FLANGE 0.150 LENGHT LBL33 BETWEEN STR5L AND STR6L I.A.W SRM 51-10-02-0G-0;[03] REQUEST HFEC TO VERIFY CRACK FREE CONDITION ON TRIMMED AREA;[04] HFEC INSPECTED CUTOUT AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS2353 CAL DUE: 01/23;[05] VERIFIED CORRECTIVE ACTION #1; 2;[06] REPAIRED DAMAGE ON CRACKED FRAME AT BS312 LBL33 BETWEEN STR5L AND STR6L I.A.W EA 22-153-01244 ATTACHED COSTUMER CARD TTG8Q00F4KR5;[07] VERIFIED CORRECTIVE ACTION ITEM 6.<BR>VERIFIED MEASUREMENTS TABLE. FAULT COMPLETE.