What was found
CORROSION FLOOR STRUCTURE INNER CHORD LOCATED BS967 TO BS986 RBL48 AND WL208 AT AFT GALLEY AREA 2022-518164 / [01] REPLACED INNER CHORD LOCATED BS 907 TO BS 1006 RBL 48 AND WL208 AT AFT GALLEY AREA. IAW B737-700 SRM 51-40-02 AND DWG # 147A8501; SHEET 93 REV ?A?.;[02] CORRECTED STEP 1.<BR>REPLACED INNER CHORD LOCATED BS 907 TO BS 1006 RBL 48 AND WL208 AT AFT GALLEY AREA. IAW B737-700 SRM 51-40-02 AND DWG # 147A8501; SHEET 93 REV ?A?. 'SEE INDIVIDUAL SIGNOFF BELOW'.;[03] CERTIFIED RII WORK PERFORMED. <BR>SEE INDIVIDUAL SIGNOFFS BELOW.