What was found
FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS CORROSION AROUND NUT PLATE HOLE BS500F+7 RBL24.5 WL156 / [01] UPDATED MEASUREMENT TABLE FOR PICTURE OF CORROSION ATTACHED;[02] EVALUATED CORROSION AT BS 500F+7' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING ATS TOOL ID ATS2678 EXP 4/2023;[03] VERIFIED APPLICABILITY OF SRM 53-00-53-1A-2.;[04] VERIFIED CORRECTIVE ACTIONS 1-3<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VERIFIED PICTURE OF CORROSION IS ATTACHED TO THE FAULT<BR><BR>VALIDATED APPLICABILITY OF SRM 53-00-53-1A-2.;[05] REMOVED R/H FLOOR TO SIDEWALL SUPPORT AT BS 500A TO 500I PER SRM 51-40-02-0G-0;[06] LOCATED AND DRILLED NEW R/H FLOOR TO SIDEWALL SUPPORT BS 500A TO BS 500I RBL 25 WL 156 PER SRM 51-40-05-0G-0; AND DWG 143A7500. OK TO INSTALL FLOOR TO SIDEWALL SUPPORT;[07] VERIFIED CORRECTIVE ACTION 6.<BR>OK TO INSTALL;[08] INSTALLED R/H FLOOR TO SIDEWALL SUPPORT AT BS 500A TO BS 500I RBL 25 WL 156 PER SRM 51-40-02-0G-0; DWG 143A7501 AND DWG 143A7500;[09] VERIFIED CORRECTIVE ACTION 8;[10] VERIFIED MEASUREMENT TABLE