What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 LBL46 WL208.1 FWD GALLEY AND LAV 2022-561903 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 LBL46 WL208.1 FWD GALLEY AND LAV AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG 141A5400 REV. -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 LBL46 WL208.1 FWD GALLEY AND LAV AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG 141A5400 REV. -. <BR>RII ACCOMPLISHED <BR>SEE INDIVIDUAL SIGN OFF BELOW.