What was found
FITTING AT ACB BS 947.5' LBL 10 CRACKED (P/N 149A8113-6) / [01] REMOVED FITTING AT ACB BS 947.5 LBL 10 IAW SRM 51-40-02<BR><BR>CRACK AT ACB BS 947.5 LBL 10 IT IS OUT OF LIMITS WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[02] CRACK ON FITTING AT ACB BS 947.5 LBL 10 IT IS OUT OF LIMITS WILL BE REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[03] RECEIVED NEW FITTING P/N:149A8113U6 LOT: 1503744-9 PO/N:883836/9 AND LOCATED AND DRILLED AT ACB BS 947.5 LBL 10 IAW SRM 51-40-05 AND DWG: 148A8113 ID:0005 REV:A ; REQUEST OK TO INSTALL NEW FITTING.;[04] VERIFIED CORRECTIVE ACTION #1; #2; #3.<BR>VERIFIED OK TO INSTALL FITTING.;[05] INSTALLED NEW FITTING AT ACB BS 947.5 LBL 10 IAW SRM 51-40-02 AND DWG:149A8103 ID:0005 REV:-;[06] VERIFIED CORRECTIVE ACTION #5.<BR>VERIFIED MEASUREMENTS.