What was found
CRACKED LOWER L/H COMPOSITE BULKHEAD AT BS663 LBL33 WL161. REMOVED DAMAGED & CONTAMINATED FIBERGLASS PLIES FROM 5EA AREAS. PREPARED AND CLEANED 5EA AREAS FOR REPAIRS. WORK ACCOMPLISHED IAW SRM 51-70-04-2R-10 PAR 4.A-C. INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1; 2 AND 3. VERIFIED MEASUREMENTS TABLE. FABRICATED REPAIR PLIES IAW SRM 51-70-04-2R-10 PARAGRAPH 4.D. INSPECTED AND VERIFIED CORRECTIVE ACTION 5. OKAY TO INSTALL REPAIR PLIES PER SRM 51-70-04-2R-10.VERIFIED MEASUREMENTS TABLE. INSTALLED PLIES, VACUUM BAGGED PLIES AND VERIFIED SATISFACTORY 5X5 IAW SRM 51-70-04-2R-10 PARAGRAPH 4.D-E. UNBAGGED PLIES AND LIGHTLY SANDED IAW SRM 51-70-04-2R-10 PARAGRAPH 4.F AND H. PERFORM POST CURE NDI IAW SRM 51-70-04-2R-10 PARAGRAPH 4.G; POST REPAIR UT INSPECTED PER NDT PART 4 51-00-02. NO DEFECTS FOUND. REFINISHED REPAIR AREAS IAW SRM 51-70-04-2R-10-2R-10 PARAGRAPH 4.H