What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT IN AFT CARGO BAY BS 727A-767, RBL 21. REMOVED CORROSION ON SUPPORT AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PAR 4A FIG 103 DETAIL E. REPLACED PART IAW SRM 51-10-02 PAR 9. FABRICATED, LOCATED, AND DRILLED NEW SIDEWALL SUPPORT IAW SRM 51-40-05 AND DWG 146A7502 REV-. APPLIED CHEMICAL CONVERSION COATING AND PRIMER. IAW SRM 51-20-01. ASSEMBLED FLOOR TO SIDE WALL SUPPORT IAW SRM 51-40-02, SRM 51-40-10; DWG 146A7502 REV- .