What was found
R/H B.S. 663 VAPOR BARRIER IS CRACKED ON UPPER EDGE MID SPAN / FABRICATED REPAIR PLIES USING FIBERGLASS 9-3; STYLE 1581; LOT# 1502472-1 IAW SRM 51-70-04-2R-10 PAR 4.D. OK TO INSTALL REPAIR PLIES.;[06] VERIFIED CORRECTIVE ACTION 5<BR><BR>OK TO INSTALL REPAIR PLIES;[07] INSTALLED PLIES WITH BMS8-301 CLASS 2 LOT NUMBER 1506171-2; VACUUM BAGGED PLIES AND VERIFIED 5X5 USING VACUUM GAUGE ID: ATS2796 DUE: 10/2023; WORK PERFORMED IAW SRM 51-70-04-2R-10 PARAGRAPH 4.D-E;[08] INSPECTED AND VERIFIED CORRECTIVE ACTION 7. 5X5 LEAK CHECKED PASSED PER 51-70-04-2R-10.;[09] CURED PLIES USING THERMOMETER ID: ATS2663 DUE: 09/2023 UNBAGGED PLIES AND LIGHTLY SANDED PLIES; WORK PERFORMED IAW SRM 51-70-04-2R-10 PARAGRAPH 4.F AND H;[10] INSPECTED AND VERIFIED CORRECTIVE ACTION 9.;[11] PERFORM POST CURE NDI IAW SRM 51-70-04-2R-10 PARAGRAPH 4.G;[12] POST REPAIR UT INSPECTED PER 737NDT PART 4 51-00-02. NO DEFECTS FOUND. TOOL E650 ATS2031 DUE 03/2023;[13] REFINISHED REPAIR AREAS IAW SRM 51-70-04-2R-10-2R-10 PARAGRAPH 4.H;[14] VERIFIED CORRECTIVE ACTION 13;[15] VERIFIED CORRECTIVE ACTION 13