What was found
FWD CARGO BAY INTERCOSTAL CRACKED BS 500A - 500B WL 155 LBL 25. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; PAR. 4. C. (2). (A). FIG.103 DETAIL C. REMOVED INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED A NEW INTERCOSTAL IAW SRM 51-40-02-0F-0 AND DWG 143A7505. FABRICATED REPAIR ANGLE IAW SRM 53-30-53-2R-1, TABLE 201, ITEM 2, FIG. 202. APPLIED CHEMICAL CONVERSION COATING IAW SOPM 20-43-03. APPLIED PRIMER TO ANGLE REPAIR IAW SOPM 20-43-03 AND SOPM 20-41-02. INSTALLED REPAIR ANGLE AND INTERCOSTAL IAW SRM 53-30-53-2R-1 REPAIR 1 STEP 4 M-N-O-P AND DWG 143A7505 REV B.