What was found
CORROSION. @ FASTENER HOLE FLOOR BEAM STA 986.5 RBL-5 MKD DOT / [01] REMOVED CORROSION AT FASTENER HOLE FLOOR BEAM STA 986.5 RBL-5 AS PER REFERENCE B737-700 SRM 51-10-02-0G-0;[02] VERIFIED STEP 1.;[03] PERFORMED UT THICKNESS INSP. ON REWORKED AREA @ FASTENER HOLE FLOOR BEAM STA 986.5 RBL-5 IAW B737 NDT PART 4 51-00-00 PROC. 3. MIN THICKNESS .116'; EQUIP: OLYMPUS 27MG CAL DUE: 4/23 B/C 172139;[04] JOB WILL BE ACCOMPLISHED IN THE ITEM TTG8Q00FKDE6. PER REF EA M-21-153---612;[05] JOB WILL BE ACCOMPLISHED IN THE ITEM TTG8Q00FKDE6. PER REF EA M-21-153-00612;[06] VERIFIED STEP 5.