What was found
CORROSION ON BS 947 FLOORBEAM LBL 26, WL 208 UPPER SURFACE. FABRICATED REPAIR, LOCATED & DRILLED. FLAP PEENING CUT EDGE ON ORIGINAL FLOORBEAM AND NEW TEE FITTING. APPLIED CHEMICAL CONVERSION COAT & PRIMED IAW SRM 53-70-51-2R-5, REP 5, ALT.2. PAR 4.C(3)-4.K. INSTALLED REPAIR IAW SRM 53-70-51-2R-5, REP 5, ALT 2, PAR 4.L-M.