What was found
ELECTRIC TRIM INOPERATIVE AFTER TAKEOFF. HORIONTAL STABILIER TRIM. / [01] -SPEED TRIM FAIL LIGHT ILLUMINATES ON RECALL.<BR>-NO C/B?S POPPED.<BR>-FAULT MESSAGE 22-11182. (DFCS BITE);[02] R&R STAB TRIM CUTOUT RELAY (R384) OPS CHECK AND CLOSE UP REQUIRED.;[03] PERFORMED FIM 22-13 TASK 813. R&R STAB TRIM CUTOUT RELAY (R384) PER FIM. OPS CHECKS AND CLOSE UP REQUIRED.;[04] REMOVED AND REPLACED STABILIZER TRIM ACTUATOR IAW AMM 27-41-71 <BR>AND PERFORMED OPS CHECKS IAW AMM 27-41-00 AND CLOSED UP CENTER PANEL